12. (from step 11)
Did the Certify service aid fail again?
NO
a. Ask the user to recreate the array.
b. Go to step 22 on page 467.
YES
a. Exchange the failing disk drive for a new one (see Exchanging Disk
Driveson page 319).
b. Go to step 37 on page 473 to add the disk drive to the group of disk
drives that are available for use by the RAID manager.
13. (from step 4)
An array is in the Degraded state if one member disk drive of the array is missing,
or has failed, and a write command has been sent to that array. When an array is
in the Degraded state, its data is not protected.
a. Type smitty ssaraid and press Enter.
b. Select Change/Show Use of an SSA Physical Disk.
c. Go to step 14 on page 461.